Rugged, Outdoor Rated Flashing Beacon
GL10

Rugged design for use in harsh conditions, such as construction machinery, with exceptional visibility in bright sunlight

  • Voltage Input
  • CAN communication control
  • Φ100
  • Signal Light
  • Flashing (Strobe)
  • IP69K
  • Red
  • Amber
  • Green
  • Rugged, Outdoor Rated Flashing Beacon GL10
  • Rugged, Outdoor Rated Flashing Beacon GL10
  • Rugged, Outdoor Rated Flashing Beacon GL10
  • Rugged, Outdoor Rated Flashing Beacon GL10
  • Rugged, Outdoor Rated Flashing Beacon GL10

Rugged Construction


Superior Resistance to Vibration and Impact

Vibration test

- Vibration Resistance 110m/s2
- Impact Resistance 1,000m/s2

Superior Resistance to Dust and Water

Water tight test

- IP69K construction for enhanced protection from dust and water
- Suitable for high-temperature and high-pressure cleaning

>>Water tight test video

 

Superior Resistance to Vibration and Impact

Vibration test

- Vibration Resistance 110m/s2
- Impact Resistance 1,000m/s2

Superior Resistance to Dust and Water

Water tight test

- IP69K construction for enhanced protection from dust and water
- Suitable for high-temperature and high-pressure cleaning

>>Water tight test video

Resistant to temperature and humidity variations

Operating Ambient Temperature: -40 to +85℃
Ventilation function prevents fogging due to condensation

Ventilation function

Resistant to temperature and humidity variations

Operating Ambient Temperature: -40 to +85℃
Ventilation function prevents fogging due to condensation

Ventilation function

Complies with various international standards, including EMC (electromagnetic compatibility): ISO13766-1 and environmental testing: ISO16750, regulated for vehicles

 

Projects Three Colours from a Single Unit

  • Operating status can be determined with a combination of 3 light colours and different flash patterns
  • Distinct flash patterns can be allocated for each colour to assist individuals with colour vision impairment

*Above 3 flash patterns are pre-configured and fixed for voltage controlled models
*13 flash patterns can be configured for CAN communication models

>>Flash pattern video

 

Two Control Options Available

CAN Communication Control

  • Compatible with SAE J1939: CAN communication protocol highly suited for construction machinery.
  • 13 types of flash patterns and 4 levels of dimming can be configured through communication control.
  • Operating status of light colour, including flash pattern, can be monitored and acquired through CAN communication.
  • Automatic detection and connection at 250 kbps / 500 kbps

Standard Voltage Control

  • Standard Voltage Control
  • Non-communication type, controllable with conventional voltage application
  • 3 flash patterns are fixed and pre-configured for optimal status indication in red, amber and green.

*Status acquisition function is not supported for this model

 

Applications

How to Order

 

Product List

Model Rated Voltage Luminous colour Control spec Flash pattern
GL10-M1NC1-T 12V-24V DC 3 colours
(Red, Amber, Green)
CAN communication control
(J1939)
Selectable from 13 patterns
GL10-M1N-T Standard Voltage Control Red : Triple flash
Amber : Double flash
Green : Firefly flash pattern [ Slow (single) flash ] 

(*) The download service of the data on this site is deemed to have agreed to the following "".

(*) The download service of the data on this site is deemed to have agreed to the following "".

TERMS AND CONDITIONS FOR DATA DOWNLOAD

1.Ownership of rights

Copyright and other intellectual property rights in the data downloadable from this site belong to PATLITE Corporation (“PATLITE”) or the right holders from whom PATLITE has obtained necessary licenses for the use thereof.

2.Use of data

Users of this site, who are also registered members of PATLITE Web Member, (“User”) may use the data downloaded from this site (“Downloaded Data”) free of charge and on a non-exclusive basis, solely in accordance with these Terms and Conditions for Data Download (“Terms”).

3.Purpose

The data disclosed on this site (“Disclosed Data”) and Downloaded Data may be used only for the following purposes:

  1. Messages, melodies, alarm sounds, and other audio data (“Audio Data”) or software data (“Software Data”). Users of PATLITE products may transfer Audio Data and/or Software Data to PATLITE products and run such data on PATLITE products only.
  2. CAD data of PATLITE (“CAD Data”) or PATLITE product specification data (“Products Specification Data”). Users of PATLITE products may consult such data for the purpose of repair or renewal of PATLITE products. Prospective buyers of PATLITE products may also use the data for evaluation.

4.Prohibited acts

  1. Downloaded Data may not be reproduced, modified, altered, decomposed, disclosed, replicated elsewhere, assigned, or loaned in whole or in part.
  2. Audio Data must not be used for any purpose other than those stated in Article 3; Audio Data must not be used with non-PATLITE products.
  3. Software Data must not be used for any purpose other than those stated in Article 3; Software Data must not be used with non-PATLITE products.

5.Notes on Disclosed Data and Downloaded Data

Please acknowledge the following before using Disclosed Data and/or Downloaded Data:

  1. Not all models released by PATLITE in the past are disclosed as Disclosed Data on the site.
  2. Some products included in Disclosed Data may have been discontinued or may no longer be available for sale.
  3. Disclosed Data reflects the state of products at the time of their release.
  4. PATLITE reserves the right to determine the type and content of Disclosed Data and the period of availability.
  5. Software Data is not supported by all computer appliances; some may not import the data in full or in part.
  6. CAD Data do not guarantee the specifications and/or performance of the corresponding products.
  7. PATLITE does not warrant that the values extracted from the drawings in the CAD Data match actual products.
  8. The CAD Data is provided in an intermediate file format for exchanging CAD data, which may not be supported by all applications. Some CAD applications may fail to import the data in full or in part.
  9. If the User intends to export or provide Downloaded Data to non-residents, they must comply with the Foreign Exchange and Foreign Trade Act of Japan, the US Export Administration Regulations, and other applicable laws, and complete all necessary procedures.

6.Downloading CAD data

  1. PATLITE does not guarantee the consistency of values extracted from CAD drawings with actual products. For specifications and dimensions, refer to product specifications.
  2. 2D data is provided in DXF format (Ver.R12/L12).
  3. 3D data is provided in the following formats:
    A. IGES;
    B. STEP;
    C. PARASOLID.

7.Downloading Product Specification Data

Safety precautions for PATLITE products are included in the Product Specification Data or in separate hard-copy attachments. However, only product specifications are available on this site, and safety information in such attachments may not be provided online. These precautions may change according to legal requirements.

8.Termination or change of downloading service

Services on this site may be withdrawn or changed without notice. PATLITE reserves the right to revise the Terms without notice. Any revised Terms will apply immediately upon announcement on this site.

9.Termination of utilizing agreement

PATLITE may terminate the agreement if a User violates the Terms, commits any act against public order or laws, defames PATLITE, or damages PATLITE’s services. In such cases, the User must immediately cease using all Downloaded Data. This provision also applies if the User loses membership status.

10.Limitation of Liability

PATLITE is not liable for any damages resulting from the use or inability to use services on this site (including but not limited to data loss, suspended operation, and loss of business information), even if the risk of damage or third-party claims was known in advance.


pagetop